Product
Standardized Oculomotor Neuro-ophthalmic Disorders Assessment
SONDA is an eye-tracking platform that combines multiple oculomotor assessments and eye movement perimetry into a single rapid test. A two-minute intuitive test provides an objective read on visual function, cleared for the diagnosis and staging of glaucoma.
The platform
Three components, one platform.
Loading 3D model…
Medical-grade display with photometric calibration
Custom electronics for fast connectivity and precise time-sync
On-board processor with dedicated NVIDIA® GPU
Inertial measurement unit for head movement tracking
Custom magnetic prescription lenses and occluders
Infrared eye-tracking sensors @200Hz
The SONDA Hub presents the continuous visual stimulus and processes the recorded gaze in real time. It is the hardware component that pairs with the CE-marked SONDA software.
Medical-grade hub for visual stimulationThe Class I, EN 60601-compliant unit that drives the test and runs the analysis.
The SONDA Hub presents the continuous visual stimulus and processes the recorded gaze in real time. It is the hardware component that pairs with the CE-marked SONDA software.
Wearable eye-tracking sensorsLightweight glasses that track both eyes with complete freedom of motion.
Infrared eye-tracking cameras integrated into a lightweight frame. No chin rest, no fixed head position, and no expert operator required to fit them.
Neurovisual reportA clinical read on visual function, ready in minutes.
Patented algorithms turn raw gaze data into spatio-temporal properties, then into a structured report a clinician can act on the same day.
Interactive 3D view is not available in this browser. Product photography coming soon.
SONDA in action
See through the eyes of your patient.
- Patient wears glassesNo calibration or setup needed
- Visual stimuli presentedNo complex task: just follow with your eyes
- Eye movements capturedInfrared sensors record objective oculomotor data
- Real-time analysisPatented algorithms process diagnostic biomarkers
- Clinical report generatedSimple, actionable output
Output
Actionable results within minutes.

Every test produces a structured visual function report. The risk index provides clear, actionable output, immediately identifying if the patient presents symptoms of visual function loss compatible with glaucomatous damage. For in-depth analysis, the full oculography recording provides metrics on data quality, blinking frequency and saccades dynamics (peak velocity and amplitude) that can help in understanding the more difficult cases.
SONDA is highly accurate and reliable; see the clinical evidence.
Specifications
Specifications: Regulatory, Technical, Clinical.
Regulatory
- Software Certification
- CE-marked, MDR Class IIa
- Hardware Certification
- CE-marked, MDR Class I, EN 60601-1
- Quality Management
- ISO 13485:2016
Technical
- Eye-Tracking Mode
- Monocular L/R, binocular
- Display Luminance
- Photometrically calibrated
- Calibration
- True calibration-free
- Operating Distance
- 35 to 60 cm
- Sampling Frequency
- 200 Hz gaze/IMU
- Dimensions, Hub
- W66 x H53 x D32 cm
- Accuracy
- 1.3 deg
- Connectivity
- Up to 1000 Mb/s
- System Latency
- < 5 ms, photodiode calibrated
Clinical
- Diagnostic Accuracy
- 97% global AUC; 86% early, 95% moderate, 96% late
- Testable Field of View
- 160 deg horizontal, 90 deg vertical
- Learning Effect
- None; reliable from the first measurement
- Head Stabilization
- Virtual chinrest, compatible with a standard chinrest
- Correlation with HFA
- r = 0.78 (p < 0.001)
- Grid Pattern
- 24-2, Esterman (more to come)
- Test Duration
- 80 to 120 seconds per eye
For existing customers
Access your SONDA portal online.
Log in to the SONDA portal to manage your device, review reports and track testing history.